Clip-systemStaple Plate EPS 045
MC Therm

Underfloor heating staple plate EPS 045 – folding plate 20–50 mm

The EPS 045 stapling panel from MC Therm is the most economical system panel for underfloor heating in stapling systems. As a foldable panel made of EPS hard...

€29,47€2,95 /m²
Inkl. 19% MwSt. · Versandkostenfrei ab 1500 €· INSTALLMENT PAYMENT POSSIBLE
Auf Lager
Only 12 sets available
Delivery by
✓Staple Plate EPS 045 – Affordable Underfloor Heating Insulation
✓4 kN/m² – suitable for normal residential areas
✓28 dB impact sound insulation – with 20 mm tacker plate
✓5 cm grid film & DIN 18560 moisture protection
WLG-Klasse: WLG 045
dimension: 20-2 10m² PU
Do you want to save 10% on your purchase? Then configure your complete set now in one of our configurators.
→

Free shipping ab 1500 € Auftragswert
5-year warranty on pipe & system
30-Day Returns risk-free
Technical Consulting Mon–Fri · 8 AM–5 PM
ZahlungAmerican Express Apple Pay BLIK EPS Google Pay iDEAL Wero Klarna Maestro Mastercard PayPal Shop Pay Union Pay Visa

The EPS 045 stapling panel from MC Therm is the most economical system panel for underfloor heating in stapling systems. As a foldable panel made of EPS hard foam with a thermal conductivity group of 045, it offers functional thermal insulation for residential areas with normal requirements – the most affordable option in the MC Therm product range.

With a compressive strength of 4 kN/m² and an impact sound reduction of 28 dB (at 20 mm), the EPS 045 stapling panel impresses with its excellent price-performance ratio. The coated cover film with a 5 cm installation grid and 3 cm film overlap ensures moisture protection according to DIN 18560.

Available in 6 thicknesses (20–50 mm) as a foldable panel (1,000 × 2,000 mm). Dynamic stiffness 20 MN/m³. Directly from the OEM manufacturer MC Therm Chemnitz – no intermediaries, best prices.

Technische Daten

Material
EPS rigid foam EPS 045 DES sm
Thermal conductivity group
WLG 045 (λ = 0.045 W/mK)
Compressive strength
4 kPa (4 kN/m²)
Impact Sound Reduction ΔLw
28 dB (at 20 mm)
Dynamic stiffness
20 MN/m³
Building material class
B2 (normally flammable)
Publisher grid
5 cm printed
Film overlap
3 cm at butt joints
Moisture protection
DIN 18560
Thickness (Variants)
20 / 25 / 30 / 35 / 40 / 50 mm
★★★★★
""
W
Wera Trub08.07.2025

Shipping

  • Collection in Chemnitz possible (free of charge)
  • Shipping for orders from 200 m² – please inquire at shop@mc-therm.de
  • Delivery time: 3–7 business days after order confirmation
  • Shipping method: Freight forwarder (pallet)

Warranty

  • 5-year warranty on EPS material and film covering
  • Declaration of conformity available on request
  • Product complies with the requirements of DIN EN 13163 (EPS insulation materials)
  • Moisture protection according to DIN 18560 due to 3 cm film overlap
What is a tacker plate and why is it needed for underfloor heating?

The staple plate (also known as a folding plate) is the system insulation panel for underfloor heating stapling systems. It insulates against heat loss downwards and dampens impact sound. Heating pipes are secured with stapler pins in a 5 cm grid. After that, the screed is applied – and the underfloor heating is complete.

Which tacker plate for 20mm - which version to choose?

For a 20 mm installation height, we recommend the EPS 045 variant 20-2 (WLG 045, 4 kN/m²) or EPS 035 variant 20-2 (WLG 035, 10 kN/m²) tacker plate. EPS 045 is the more affordable standard choice, while EPS 035 offers better insulation values with the same space requirement.

How is the tacker plate laid on the subfloor?

The staple plates are butted together, and the film overlap of 3 cm is placed over the adjacent plate. Ensure edge strips are fitted to walls. Then, fix the heating pipes in the laying grid and, after a pressure test (6 bar, 30 min), apply the screed.

Can I install staple plates on old wooden floors or tiles?

Yes, staple plates can be laid on a level, load-bearing substrate – on concrete, old screed, or wooden floorboards. The substrate must be dry, level (max. 3 mm/m unevenness), and load-bearing. For wooden floors, ensure sufficient construction height and structural integrity.

How many staples do I need per square meter of tacker board?

Approximately 2–3 staple pins are needed per running meter of heating pipe. With a pipe spacing of 15 cm over 10 m², you will need approximately 700 m of pipe and accordingly 1,400–2,100 staple pins. Staple pins are available for 16 mm and 17 mm heating pipes.


Your benefits at a glance

1

Cheapest Staple Panel in our range – WLG 045 for budget-optimized residential construction projects

2

28 dB impact sound insulation (at 20 mm) – excellent sound insulation for residential buildings

3

Folding technique – easy transport and quick installation on the construction site

4

DIN 18560 moisture protection with 3 cm foil overlap and scrim

Areas of application

New buildrenovationdetached housewet screedunderfloor heatingbudget

Free & non-binding

Personal consultation

Our team offers free advice – by phone, email, or directly in the chat. We help you with system selection, quantity calculation, and planning.

25+ Years of experience
5,000+ Projects
4.9★ Average rating
10 yrs. Warranty