What you need for the retrofit
Materials needed
- →Actuators E30NC-230 (one per heating circuit/zone — thread M30×1.5)
- →Thermostats: Easy-230 (wired) or EONE-230V (ZigBee), depending on the system
- →Control box: ECB8-230V (wired, 8 zones) or ECB62-ZB (ZigBee, 8 zones)
- →For ZigBee system: EGATE-PRO Gateway (once per household)
- →Screwdriver, Allen key or open-end wrench AF 30 for actuator mounting
- →Electrician's terminals and cables 3×0.75 mm² (actuator to control box), approx. 3–5 m per zone
- →Multimeter for voltage testing (230V vs. 24V at the distributor)
Check prerequisites at the distributor
- →Heating circuit manifold accessible (screed distributor box or wall box opened and cleaned)
- →Check the voltage at the distributor: 230V (standard) or 24V (bathrooms/wet rooms). Actuators must be compatible!
- →Check thread on the manifold valve: Standard M30×1.5 (compatible with E30NC-230). Alternative threads require an adapter.
- →Determine the number of heating circuits — each heating circuit requires its own actuator and thermostat
- →Cables from the distribution box to each thermostat mounting location are present or can be retrofitted
Before you start: Check distributor & voltage
Before any retrofit, two checks are mandatory: First, the voltage at the heating circuit manifold — most living spaces operate at 230V (suitable for E30NC-230), while damp rooms like bathrooms require 24V (suitable for ECB8-24V and E30NC-24). Second, the thread format of the valves: The standard is M30×1.5 — compatible with all ENGO actuators, without an adapter. Deviating threads (M28×1, Danfoss RA) require an adapter (approx. €2–3/pc).
Retrofitting: With or without control line?
Cost overview: Material + Electrician + Funding
| Item | 1 Zone Wired | 1 Zone ZigBee Wireless |
|---|---|---|
| Thermostat | €25 (Easy-230) | €68 (EONE-BAT) |
| Control box (proportionally 4 zones) | €14 (ECB8-230V/4) | €39 (ECB62-ZB/4) |
| Gateway (proportionally 4 zones) | — | €16 (EGATE-PRO/4) |
| Actuator | €10 (E30NC-230) | €10 (E30NC-230) |
| Electrician (approx.) | €30–50 | €20–30 |
| BAFA 15% (on material) | −€7 to −€9 | −€10 to −€13 |
| Effective costs/zone | approx. €63–80 | approx. €140–160 |
- BAFA BEG EM: 15% (20% with iSFP) for thermostats, control boxes, actuators. Submit application BEFORE commissioning a craftsman.
- KfW 458 (from July 2026): Funding for simultaneous heat pump installation — up to 80% funding rate (income-dependent), max. eligible costs €28,000.
- Tax deductibility: 20% of craftsman costs deductible over 3 years (§ 35a EStG), max. €40,000 basis.
- Both programs can be combined — but no double funding for the same measure.
Retrofit Control System: 5 Steps
Step 1: Inspect the manifold and turn off the heating: Turn off the heating system at the boiler or heat pump. Locate the heating circuit manifold in the distribution box—usually in the cellar, utility room, or a wall cabinet. Check how many heating circuits are present (each connection = one circuit). Note down the designations, if available (e.g., 'Bathroom Upper Floor', 'Living Room'). Check the valve heads: Do the valves already have heads (handwheels or old actuators)? These will be removed.
Step 2: Remove old valve heads, install new actuators: Unscrew old valve heads (handwheels or previous actuators) — counter-clockwise for M30×1.5 threads. Ensure that the valve does not permanently close when removing: the valve pin should move freely. Screw on the new E30NC-230 actuator (clockwise, hand-tight). Connect 3×0.75 mm² cable (2× 230V supply, 1× neutral) to the actuator — use terminals L, N, PE. Route the cable through the cable guide of the distribution box to the control box mounting location.
Step 3: Install junction box: Mount the control box (ECB8-230V wired or ECB62-ZB ZigBee) in or next to the distribution box. Connect the 230V power supply to the control box – always by an electrician for fixed house installations. Connect the actuator cables to channels 1–8 of the control box – channel 1 corresponds to zone 1 (first heating circuit). Label each zone: use adhesive strips on the control box with room name and circuit length.
Step 4: Mount and wire thermostats: Mount each thermostat in the room it controls—mounting height approx. 1.5 m above the floor, not in wall niches, behind curtains, or above heat sources. Connect wired thermostats (Easy-230) to the corresponding zone of the control box via a 2-wire cable (230V or control voltage via BUS). ZigBee thermostats (EONE-230V) are first paired with the EGATE-PRO via ZigBee (Step 5). The temperature sensor (built into the thermostat) requires free air circulation.
Step 5: Commission and program the system: Switch the heating back on. Switch on the control box – all actuators should open (NC = Normally Closed, i.e., closed without power; open with power). Set the desired setpoint temperature at each thermostat or program a weekly schedule via the app (ZigBee). Recommended room temperatures: living room 20 °C, bedroom 17–19 °C, bathroom 21–24 °C, children's room 20–22 °C. Observe the system for 24 hours to ensure all rooms maintain the setpoint temperature.
Costs of retrofitting control system 2026
| Component | Price |
|---|---|
| Actuator E30NC-230 (per zone) | €9.50 / piece |
| Wired Thermostat Easy-230 (per room) | €24.90 |
| Control box ECB8-230V (wired, 8 zones) | €54.43 |
| Costs 1 Zone wired (Actuator + Thermostat) | from €34.40 |
| Cost 4 zones wired complete | approx. €192 |
| ZigBee Thermostat EONE-230V (per room) | €64.09 |
| ZigBee Control Box ECB62-ZB (8 Zones) | €95.43 |
| EGATE-PRO Gateway (one-time) | €61.81 |
| Cost 4 zones ZigBee complete | approx. €380–450 |
| Payback period with 30% heating cost savings | a heating season |
230V connection: Contact an electrician
The mains connection of the control box (230V) must be carried out by an authorised electrical company if permanently installed in the house. Plug-in control boxes can be installed by the DIY enthusiast themselves. E30NC-230 actuators operate on 230V — do not forget to earth them (PE connection).
Frequent questions about retrofitting underfloor heating control
Actuators & Thermostats for Retrofitting


Thermoelectric actuator Engo E30NC-230 for underfloor heating
Actuator


EONE-230V – Smart ZigBee Room Thermostat
thermostat


Control terminal strip ECB8-230 V wired 8 zones
Control terminal block


ZigBee control terminal block 8 zones ECB62-ZB